RS-J317LF-001

Jupiter series flagship products

RS-J317LF-001

Different from traditional air cooling systems, this product adopts high-efficiency liquid cooling technology, which improves heat dissipation efficiency and ensures the stability of the battery during high current charging and discharging at 300A. The battery pack has a wide operating temperature range (charging -5°C~65°C/discharging -35°C~65°C), and can handle various global air routes with ease.

Technical Specifications

 

Nominal Voltage (V)1081.9
Voltage Range (V)840~1226.4
Nominal Energy (kWh)343.0 (14 battery modules in series)
Standard Charge/Discharge Current (A)158.5
Maximum Continuous Charge/Discharge Current (A)300
Operating TemperatureCharge: -5℃~65℃  |  Discharge: -35℃~65℃
Storage RequirementsTemperature: -40℃~60℃  |  Humidity: 5%~95%
The storage battery shall be stored in a dry, ventilated and cool environment to avoid direct sunlight, high temperature, corrosive gas, violent vibration, and mechanical impact.
External Communication PortCAN / RS485 / LAN
Class ComplianceDNV , NK
Explosion-proof MeasuresInstallation of explosion-proof valve
Cooling MethodLiquid Cooling
Leak detectionYes
NoteOne BABOX manages 6 strings in parallel at max

Ready to Experience the Perfect Solution?

Ready to Experiencethe Perfect Solution?

发送讯息获取专属方案

Let's have a chat!聊聊您的需求!